Fluorometer, Flame Photometers

DB-1276 : Atomic Absorption Spectrophotometer (Double Beam) : Rs.16,53,000

Atomic Absorption Spectrophotometer Ebert type monochromator with 1200
lines/ mm halographic grating, 0 to2nm SBW, 190-900nm Wavelength range. 8 hollow cathode Lamp turret assembly with modulated eight independent power supplies. Built in background corrector in the system using high intensity and high speed Deuterium lamp. Automatic calibration using up to maximum 10 standards and recalibration with a single standard. Direct concentration readout using different modes (K- Factor Linear regression and Quadratic regression).
Display of the signal energy in the form of BAR signal and numeric form. ABS. %
TRANS and CONG display facility.

Absorbance range from Oto 3.0 ABS. Titanium Burner of 100 mm Air-acetylene
and 50 mm N 20 – Acetylene Flames. Corrosion resistant nebulizer with Platinum –
Iridium capillary, Impact bead. Supplied with computer interface software,
cylinder, regulator, 3 standard lamps &compressor.

DB-1236 Fluorometer Digital : Rs.82,500

Display : 3 Digits, Excitation Source : 12V, 50W Tungsten Halogen Lamp
Sensitive Range : Adjustable in 4 Ranges
Primary Filters : Corning 5840 and Corning 5113 mounted on holders
Secondary Filters : Corning 4308, Corning 3486 & Corning 3385
mounted on holders.
Detector : Highly Sensitive wide range Photo Diode/ Cell
Sample Test Tube : 15mm (D) X 80mm (H)
Sample Volume Minimum : 4 ml
Power Supply : 230 V ± 10% AC, 50 Hz.
Dimension : 262 X 340 X 165 mm (Approx.) ,  Weight : 5 Kg. (Approx.)

Flame Photo Meters

Filter
Standard/ Regular
Optional
Compressor Unit
Na
K
Ca
Li
Air Supply : Oil Free Compressor
Range
0 to 100 ppm
0 to 100 ppm
15 to 100 ppm
10 to 100 ppm
Combustion : By Precision Regulator to control LPG feeding
Sensitivity
5 ppm
5 ppm
10 ppm
10 ppm

DB-1141 Flame Photometer Digital : Rs. 46,500-00
(Dual Display) With filters (Na & K)

Readout : 2½ Digit Bright Red LED Display, Repeatability:± 2 Counts
Display : Dual Display, Detector : Silicon Photo Diode
Accuracy : ± 2% upto 40 ppm, ± 5% above 40 ppm,
Filters : Narrow Band Interface Glass Filters, Ignition System : Auto Ignition
Nebulizer : Black Bakelite, Axial Flow Type,
Flame System : LPG and Dry oil free air,
Power Supply : 230 V ± 10% AC, 50 Hz. , Warm up Time : 10 Minutes
Accessories : Complete with Na & K Filter, Sample Holder, Air/ Gas Tubing along with Clamps, Chimney, 1 mm Silicon Tube for suction of sample liquid & Instruction Manual.

DB-1140 Flame Photometer Digital : Rs. 42,000-00
(Single Display) With filters (Na & K)

Readout : 2½ Digit Bright Red LED Display, Repeatability:± 2 Counts
Display : Single & Dual Display, Detector : Silicon Photo Diode
Accuracy : ± 2% upto 40 ppm, ± 5% above 40 ppm,
Filters : Narrow Band Interface Glass Filters, Ignition System : Auto Ignition
Nebulizer : Black Bakelite, Axial Flow Type,
Flame System : LPG and Dry oil free air,
Power Supply : 230 V ± 10% AC, 50 Hz. , Warm up Time : 10 Minutes
Accessories : Complete with Na & K Filter, Sample Holder, Air/ Gas Tubing along with Clamps, Chimney, 1 mm Silicon Tube for suction of sample liquid & Instruction Manual.

Flame Photometers, Bomb Calorimeter

DB-1142 Flame Photometer Microprocessor Based : Rs.97,500

Resolution : 0.1 ppm/ meq
Reproducibility : < 1% coefficient of variation for 20 consecutive samples using 10 ppm, Na set as maximum standard.
Curve Fit Accuracy : < 2% error when 3ppm Na/K and 5ppm Li, set as max. standard.
Display : 128 X 64 Graphical LCD, Average Time : In built Software
Flame System : LPG and Dry Oil free Air,
Detector : Highly Sensitive Silicon Photo Diode
Calibration : Up to 5 point calibration with curve fitting Software.
Gas Control : Adjustable with knob
Flame Failure : Auto Detection
Gas Cut Off : Gas feeding, auto cut off in case of Power Failure
Ignition System : Auto Ignition
RS-232 : Provision for Data Transfer to PC
Power : 230 V + 10%, 50 Hz AC
Dimension : 280 X 250 X 210 mm ( L X W X H ) Weight : 7.4 Kg (approx.)

Compressor Unit

Air Supply : By oil free mini Compressor unit with pressure Regulator
Combustion : LPG controlled by precision Regulator
Power : 230 V + 10%, 50 Hz AC
Dimension : 290 X 250 X 210 mm ( L X W X H ) Weight : 8 Kg (approx.)

There are some additional accessories, which are essential for the operating of Instrument and has to be arranged by customer as listed below :

1. LPG Gas Cylinder

2. Gas Regulator, required to be attached at the top/ nozzle of the Gas Cylinder.

3. Gas Pipe for LPG connection, from Gas Cylinder/ Regulator to the Instrument.

Optional : 1. “Ca” & “Li” Filter can be supplied on extra cost of each : Rs. 12,500

General
Serum
Urine
Mode
Na: 0 - 100 ppm, Up to 250 meq/L, 1 : 100 dil
Na: 0 - 200 ppm 1 : 100 dil
Na: 0 - 250 ppm 1 : 100 dil
K: 0 - 100 ppm, Up to 250 meq/L, 1 : 100 dil
K : 0 - 10 ppm 1 : 100 dil
K: 0 - 100 ppm 1 : 100 dil
Ca: 0 - 100 ppm, Up to 250 meq/L, 1 : 100 dil
Ca: 0 - 100 ppm 1 : 2 dil
Li : 0 - 100 ppm Up to 250 meq/L, 1 : 100 dil
Li : 0 – 2 ppm 1 : 5 dil
Sensitivity
General: Na : 0.5 ppm, K : 0.5 ppm, Li : 0.5 ppm, Ca : 15 ppm
Filters
Na & K,
Ca & Li ( Optional if Ordered )

DB-1308 Bomb Calorimeter Digital Microprocessor Rs.1,95,000

Automatic measurement & Mathematical calculation of calorific value/ water equivalent. USB interface for sending
data to PC. Full test report print out by inbuilt thermal printer. Weight of sample, water equivalent & sensitivity can be
set through keypad on single page. Fuse wire open indication on LCD screen. Fuse wire & cotton error adjustable.No
paper or printer door open detection. Auto indication on firing as well as after the test completed. Automatic detection
of temperature rise & fall.

Display : 128 X 64 Graphical LCD
Keypad : 20 keys
Temp. Resolution : 0.001 ºC
Internal Memory : 1000 logs with date and time
Interface : USB interface to PC
Printer : Inbuilt Thermal Printer
Time Clock : Real time clock
Power Supply : 230V+ 10%, 50Hz.AC

DB-1309 Bomb Calorimeter Digital Semi-automatic : Rs.1,16,000

Display : LED
Temp. Resolution : 0.01 ºC
Temp. Sensor : RTD
Calculation : Manual
Power Supply : 230V+ 10%, 50Hz.AC